JA-150M Wireless magnetic detector and universal transmitter with 2 inputs
- Brand::Jablotron
- Product Code: JA-150M
- Availability: In Stock
Power | 1x alkaline battery AA (LR6)1.5V 2400mAh |
---|---|
Typical battery lifetime | about 2 years |
Communication band | 868.1 MHz, JABLOTRON protocol |
RF range | approx. 300m (open area) |
The maximum length of cable for external detectors | 3 m |
Dimensions | 109 x 24 x 22 mm |
Classification | Grade 2 |
According to | EN 50131-1, EN 50131-3, EN 50131-2-6, EN 50131-5-3 |
Operational environment | EN 50131-1 II. Indoor general |
Operational temperature range | -10 to +40 °C |
Complies with | ETSI EN 300220, EN 50130-4, EN 55022, EN 50950-1 |
Can be operated according to | ERC REC 70-03 |
The JA-150M it is a magnetic wireless detector with two configurable independent inputs.
The detector is also designed to detect the handling of roller blinds.
The JA-150M inputs can be used with up to two LD-81 flood detector.
It occupies two positions in the control panel.
Description of inputs:
IN1 – Input terminal for connection to detector no. 1
IN2 – Input terminal for connection to detector no. 2
(Norm/Puls/Rol1/Rol2 can be set for IN1, IN2)
TMP – Input terminal for external tamper contact connection
COM – Common terminal for inputs IN1, IN2 and TMP
MG – Internal magnetic detector
Description of input modes:
Norm – status mode, the detector signals activation and deactivation of the input terminals
Pulse – pulse mode, the detector just signals activation (whether turning off or turning on depends on the default NO/NC standby mode).
Off – input disabled
Rol1, Rol2 – roller mode, which reacts to repeated pulses and short activating (NO) pulses with a sensitivity select-able in to two levels:Rol1 =
activation after 3 pulses within a 2 minute period; Rol2 = activation after 5 pulses within a 2 minute period. When this loop is disconnected longer then 0.5s, a
tamper alarm is triggered. After input triggering in Rol4/Rol2 mode the detector does n´t react to the next activation for 10 sec.
LD-81 – mode for connecting LD-81 flood detectors